Sectors: Finance • Information Technoloy • Government • Healthcare • Industries • Education • (show all)
The contrast values available within the Source.
The application can use this capability to inquire, set or restrict the values for CONTRAST used in the Source.
Scale the values available internally into a homogeneous range between -1000 and 1000. Make sure that a ‘0’ value is available as the Current value when the Source starts up. If the Source’s ± range is asymmetric about the ‘0’ value, set range maxima to ±1000 and scale homogeneously from the ‘0’ value in each direction. This will yield a positive range whose step size differs from the negative range’s step size.
Type: TW_FIX
Value after MSG_OPENDS: (may be remembered from a previous session)
After MSG_RESET/MSG_RESETALL: 0
Allowed Values: -1000 to +1000
MSG_GET TW_ONEVALUE TW_RANGE TW_ENUMERATION
MSG_GETCURRENT TW_ONEVALUE
MSG_GETDEFAULT TW_ONEVALUE
MSG_SET TW_ONEVALUE
MSG_SETCONSTRAINT TW_ONEVALUE
TW_RANGE TW_ENUMERATION
MSG_RESET TW_ONEVALUE
MSG_QUERYSUPPORT TW_ONEVALUE
None
Version 1.0
Where would you like to scan from? Scan in Web Apps Scan in Java Scan in .NET
The TWAIN Toolkit is distributed as is. The developer and distributors of the TWAIN Toolkit expressly disclaim all implied, express or statutory warranties including, without limitation, the implied warranties of merchantability, noninfringement of third party rights and fitness for a particular purpose. Neither the developers nor the distributors will be liable for damages, whether direct, indirect, special, incidental, or consequential, as a result of the reproduction, modification, distribution or other use of the TWAIN Toolkit.